HTI-5: the US pushes FHIR, but CDA documents stay until 2030
ONC wanted to remove 34 certification criteria to make room for FHIR APIs; the HTI-5 final rule removes 14. C-CDA documents stay in transitions of care until 2030. What it means for anyone designing integrations, in Europe too.
In December 2025 ONC, the US federal office that certifies electronic health record software, proposed to remove 34 of the 60 certification criteria in effect. The stated aim was to make room for FHIR APIs and stop spending effort on the old document-based formats. The final rule, known as HTI-5, appeared in the Federal Register on October 28. It removes 14 criteria, not 34. The rest were kept, revised or postponed, nearly always for the same reason: people working in the field explained that CDA document exchange is still, in many settings, the only exchange that works.
For anyone designing integrations, this matters outside the US too. It shows how long the move from a world of documents to a world of APIs really takes, even when the regulator has already picked the direction.
What the rule says
The final rule (91 FR 67916, RIN 0955-AA09) takes effect on December 28, 2026, with some parts from January 1, 2027. Of the 60 certification criteria, it removes 14, revises 7 and leaves the other 39 unchanged, including those added last year for e-prescribing and electronic prior authorization. The direction is spelled out in the text: certification will focus on FHIR APIs that go beyond read-only access, automate more and cover more data, including for public health and government programs.
Among the removed criteria, these are the ones that affect integration work:
- Direct, the secure messaging used between organizations to send clinical documents: its two dedicated criteria go as of the effective date, although Direct remains required until 2030 inside the transitions of care criterion (more on that below). The rule also notes that the Direct standard itself stays on the books and developers may keep using it.
- C-CDA creation performance, the criterion that tested whether the transition of care and referral summaries a system produces are conformant.
- Security tags on summary documents, both send and receive, and the document-based care plan: according to ONC, in September only 48 of 714 certified modules supported the care plan criterion.
- The older application access APIs (patient selection and all data request), from January 1, 2027. Patient selection is already required of the standardized FHIR API through SMART App Launch, and ONC considers the all data request capability widely adopted enough not to disappear without certification.
What stayed, and why
The more interesting part is what ONC wanted to remove and kept. The rule answers the comments point by point, and one reason keeps coming back: FHIR alternatives are not yet mature or available everywhere, and dropping the requirement would have pushed manual work onto clinicians.
- Transitions of care. The criterion covering C-CDA summaries exchanged when a patient moves between organizations will lose document creation, sending and receiving via Direct, and display only on January 1, 2030, not in 2027 as proposed; receiving with conformance validation stays. In the meantime, the reference to the C-CDA guide version that expired in January 2026 has been replaced with the next one.
- Clinical information reconciliation, the ability to bring medications, allergies and problems received from outside into the record. ONC wanted to remove it and instead turned it into a functional criterion: the system must still be able to reconcile, but no longer on one specific exchange format, which so far meant C-CDA. It is a way to leave the door open to FHIR solutions without taking away what works today.
- Public health. Reporting to cancer registries, which is CDA-based, health care survey submission to CDC, and electronic case reporting, which still accepts either CDA or FHIR, all stay. Commenters pointed to the risk of disrupting established reporting and to the cost of a format change for under-resourced settings.
- Privacy and security, quality management, accessibility-centered design and the implantable device list: all proposed for removal, all kept.
A whole chapter is also missing: the changes to the information blocking rules, the ban on interfering with access to and exchange of health data, that the December proposal included. The rule says proposals it does not address remain under review and may come back in later rulemaking.
Removing a criterion does not switch off a standard
One point the rule makes clear, and that is easy to misread: removing a criterion from certification neither bans nor retires the standard. It only means the government stops testing it, and ONC says so explicitly for Direct. It is reasonable to expect Direct and C-CDA to keep flowing in the US for years, just with less public checking upstream.
From an integrator’s point of view, in our experience this is the part to watch. If a vendor no longer has to prove in certification that the documents it produces are conformant, the check does not go away: it moves to whoever receives them. A malformed C-CDA document will still arrive, and someone has to catch it before it lands in the record.

What to take away
- The direction toward FHIR is clear even in the country that has pushed it hardest, but the timeline is measured in years. The US government has postponed to 2030 the exit of C-CDA documents from transitions of care. An integration project starting today should plan to handle documents and APIs side by side, not one instead of the other.
- Public health flows move slowest: registries and public agencies have fewer resources to change format, and the rule acknowledges it.
- Less checking upstream means more responsibility downstream. Anyone receiving documents should validate them on the way in and keep track of what they reject or fix, rather than assume a certification has already done it.
- The “functional” reconciliation model is useful outside the US as well: requiring a system to be able to do something, without tying it to a format, lets you change format without rewriting the requirements. In Europe the EHDS exchange format has yet to be adopted, and designing this way helps.
And one question to ask any vendor presenting its FHIR roadmap: which document-based flows will you keep supporting, until when, and who checks the quality of the documents you produce once no certification asks for it?